Quote-Ready Now Self-Performed Licensed & Insured
Commercial & Heavy-Civil Construction

Storm Sewer Installation

Storm pipes, catchbasins, maintenance holes, chambers, and outlets installed to hydraulic grade and municipal standards across the GTA and Ontario. Harrowgate Group self-performs the work to your engineered drawings, load, and finish, and completes it on site across the GTA and Ontario.

Get a Quote

Tell us what you need and we’ll get you a quote. Licensed, insured & WSIB certified · Free, no-obligation quote & on-site assessment.

Free, no-obligation quote & on-site assessment · licensed, insured & WSIB certified.

or
Call (416) 629-0721

Get a Quote

Licensed, insured & WSIB certified · Free, no-obligation quote & on-site assessment.

Free, no-obligation quote & on-site assessment · licensed, insured & WSIB certified.

or
Call (416) 629-0721
Licensed, Insured & WSIB Certified · 20 Years in Business
Licensed, Insured & WSIB-Registered Completed to code & Ontario requirements Completed on site and built to the drawings Performed & installed on site across Ontario
Why Harrowgate Group

Storm Sewer Installation, done right

Built to spec

Built to your engineered drawings, survey, and the real site conditions, not a standard package forced to fit.

Made to last

Heavy-duty steel and finishes chosen for the load, traffic, and environment on site.

Quote-ready

Send specs, drawings, or photos and get a free, no-obligation site visit and estimate with no guesswork.

Code-conscious

Installation and site work completed in accordance with Ontario requirements.

Our Process

Our Process

Storm sewer installation builds the underground pipe, catchbasins, maintenance holes, control chambers, culverts, and outlets that collect and convey rain and snowmelt to an approved quantity or quality-control system. Harrowgate self-performs excavation, bedding, pipe placement, structures, connections, backfill, and restoration across the GTA and Ontario.

  1. 01 Send your inquiry, a few photos or a description of the site.
  2. 02 We come out, assess the site, take measurements, and confirm the scope.
  3. 03 We complete the storm sewer installation on site, to the load and finish the job needs.
  4. 04 We install it, finish to grade, and clean up, one accountable crew, start to finish.
Storm Sewer Installation being built and completed on site by Harrowgate Group
Completed Storm Sewer Installation by Harrowgate Group
Finished On Site

Completed on site and built to last

Clean site work and a tidy finish, coordinated with your engineers, the other trades, and the surrounding site conditions, built to the engineered drawings and the applicable codes.

  • Coordinated with the surrounding build
  • Durable finishes for real-world wear
  • Quote-ready support from scope to completion
FAQ

Storm Sewer Installation FAQ

How is storm sewer size and slope determined?

The civil engineer models catchment runoff, inlet capture, pipe capacity, tailwater, storage, outlet control, and hydraulic grade line for the required storm events. Harrowgate builds the resulting diameters, slopes, and elevations. Field changes are not made by simply steepening a pipe because downstream capacity, cover, crossings, and control performance may be affected.

Why do new storm sewers fill with sediment during construction?

Unstabilized areas produce high sediment loads, and open catchbasins or pipe ends become convenient collection points. Harrowgate uses inlet protection, temporary plugs, diversion, stabilized access, progressive cleaning, and erosion controls to keep material out. The network is inspected and cleaned before acceptance rather than relying on the first major rainfall.

What is a storm sewer hydraulic grade line?

It represents the water level and pressure condition through the drainage system during a design event. If it rises above a pipe crown, the sewer is surcharged; if it reaches a low opening or building elevation, flooding can result. Harrowgate preserves designed inverts, control elevations, storage, and outlet conditions that the model assumes.

How are catchbasin elevations coordinated with paving?

Initial structures are set to planned grade with adjustment capacity retained. After curb and base asphalt establish reliable control, frames and grates are brought to final elevation and crossfall. Harrowgate surveys the surrounding apron and lead invert, because a grate at the correct number can still miss runoff if pavement grades bypass it.

What testing is used for storm sewer installation?

The specification may require visual inspection, CCTV, deflection testing for flexible pipe, leakage checks, structure inspection, cleaning, and survey confirmation. Large culverts or storage systems can have separate joint and watertightness criteria. Harrowgate prepares each reach, corrects deficiencies, and records acceptance before final restoration blocks access.

Can stormwater be discharged during construction?

Only through the applicable approval and municipal rules. Pumped water may require settling, filtration, sampling, flow control, or off-site management depending on source and quality. Harrowgate identifies the authorized discharge point, protects against erosion, monitors the treatment setup, and prevents sediment-laden water from being sent directly into a sewer or watercourse.

What documents are needed for a storm sewer quote?

Provide plan and profile, stormwater report, pipe and structure schedule, outlet and control details, municipal specifications, groundwater information, environmental approval conditions, erosion-control plan, testing criteria, utility crossings, traffic staging, and restoration sections. Final grading and curb plans are needed to assess inlet adjustment and overland drainage interfaces.

Our Work

See real projects across Toronto & Ontario

Commercial and heavy-civil construction, self-performed for developers, contractors, property managers, and municipalities.

View Our Projects

Get a quote for storm sewer installation

Send drawings, a site plan, or a description of the scope. Harrowgate Group is licensed, insured, and WSIB certified.

(416) 629-0721

Licensed, Insured & WSIB Certified · Self-performed and documented on every job

Send your project details

Tell us what you need and we’ll get you a quote. Licensed, insured & WSIB certified · Free, no-obligation quote & on-site assessment.

Free, no-obligation quote & on-site assessment · licensed, insured & WSIB certified.

or
Call (416) 629-0721

Companies We've Worked With

Trusted by Leading Organizations

Harrowgate Group delivers commercial and heavy-civil construction for developers, contractors, institutions, municipalities, and property groups across Ontario.

Popeyes logo Popeyes
Tim Hortons logo Tim Hortons
Subway logo Subway
University of Toronto logo University of Toronto
Madison Group logo Madison Group
RioCan logo RioCan
Women's College Hospital logo Women's College Hospital
Starbucks logo Starbucks
Mazda logo Mazda
TD Bank logo TD Bank
City of Toronto logo City of Toronto
Popeyes logo Popeyes
Tim Hortons logo Tim Hortons
Subway logo Subway
University of Toronto logo University of Toronto
Madison Group logo Madison Group
RioCan logo RioCan
Women's College Hospital logo Women's College Hospital
Starbucks logo Starbucks
Mazda logo Mazda
TD Bank logo TD Bank
City of Toronto logo City of Toronto
Call