Quote-Ready Now Self-Performed Licensed & Insured
Commercial & Heavy-Civil Construction

Electrical Duct Bank and Underground Conduit

Build coordinated underground power and communications pathways with verified geometry, protection, and pull readiness for developers, utilities, institutions, industrial operators, and general contractors. Harrowgate self-performs and manages this work across the GTA and Ontario.

Get a Quote

Tell us what you need and we’ll get you a quote. Licensed, insured & WSIB certified · Free, no-obligation quote & on-site assessment.

Free, no-obligation quote & on-site assessment · licensed, insured & WSIB certified.

or
Call (416) 629-0721

Get a Quote

Licensed, insured & WSIB certified · Free, no-obligation quote & on-site assessment.

Free, no-obligation quote & on-site assessment · licensed, insured & WSIB certified.

or
Call (416) 629-0721
Licensed, Insured & WSIB Certified · 20 Years in Business
Licensed, Insured & WSIB-Registered Completed to code & Ontario requirements Built to drawings, self-performed & completed Shipped across Canada & North America
Why Harrowgate Group

Electrical Duct Bank and Underground Conduit, done right

Built to spec

Built to your engineered drawings, survey, and the real site conditions, not a standard package forced to fit.

Made to last

Heavy-duty steel and finishes chosen for the load, traffic, and environment on site.

Quote-ready

Send specs, drawings, or photos and get a free, no-obligation site visit and estimate with no guesswork.

Code-conscious

Installation and site work completed in accordance with Ontario requirements.

Our Process

Our Process

Electrical duct banks and underground conduits provide protected, planned pathways for power, controls, communications, and site systems below roads, yards, buildings, and landscaped areas. Harrowgate self-performs and manages excavation, conduit assembly, concrete encasement, structures, grounding interfaces, backfill, testing, and restoration.

  1. 01 Send your inquiry, drawings, photos, or a description of what you need.
  2. 02 We come measure and assess the site (or work from your specs and drawings).
  3. 03 We build your electrical duct bank and underground conduit to the engineered drawings on site, finished for the conditions.
  4. 04 We return to deliver and install it, set, levelled, and done right on site.
Electrical Duct Bank and Underground Conduit being built and completed on site by Harrowgate Group
Completed Electrical Duct Bank and Underground Conduit installation by Harrowgate Group
Finished On Site

Delivered, installed, and built to last

Self-performed on site to the engineered drawings, coordinated with concrete, servicing, and the surrounding work, then a clean, documented finish.

  • Coordinated with the surrounding build
  • Durable finishes for real-world wear
  • Quote-ready support from spec to delivery
FAQ

Electrical Duct Bank and Underground Conduit FAQ

What is included in an electrical duct bank scope?

The scope includes route coordination, survey layout, utility locates, excavation, trench support, base preparation, conduit and spacers, reinforcing, grounding interfaces, concrete encasement, maintenance holes or handholes, mandrel testing, pull rope, plugs, labels, backfill, density testing, as-builts, and restoration. Harrowgate prices the issued electrical and civil design.

Why are some underground conduits concrete encased?

Concrete encasement holds the conduit array in its designed geometry and provides mechanical protection where loading, crossings, utility requirements, or system importance demand it. The electrical design establishes concrete cover, strength, reinforcing, and duct separation. Harrowgate builds and inspects the bank to those dimensions before any portion is concealed.

How do you confirm conduits are ready for cable pulling?

After the bank has cured and structures are complete, Harrowgate cleans each duct, passes the specified mandrel, installs the required pull rope, verifies identification, and seals the ends. Failed runs are investigated and corrected before handover. Test records link every conduit to its origin, destination, size, and intended service.

What controls conduit movement during concrete placement?

Harrowgate uses the specified spacers, secure supports, staged assembly, restrained stub-ups, controlled discharge, and placement methods that limit buoyancy and impact. Workers observe the array while concrete is placed. Cover, separation, bends, and entry positions are checked at hold points, and any movement is corrected before the concrete reaches final set.

Which Ontario rules apply to underground electrical work?

Ontario Regulation 164/99 adopts the current Ontario Electrical Safety Code, consisting of CSA C22.1:24 and Ontario amendments. Distribution systems also engage O. Reg. 22/04 and utility requirements. Excavation follows O. Reg. 213/91. Harrowgate coordinates the applicable design, inspections, utility rules, and civil specifications for each project.

Can duct banks cross active roads and yards?

Yes. Harrowgate stages excavation, traffic, access, trench support, temporary plating where designed, concrete placement, cure time, backfill, and pavement restoration around operating constraints. The crossing design accounts for loading and cover. We coordinate shutdowns and access windows with the owner and maintain the approved route through the work zone.

What information is needed for a duct bank quote?

Provide electrical and civil plans, duct schedules, sections, structure details, utility standards, concrete and reinforcing requirements, grounding details, inspection requirements, geotechnical information, route constraints, traffic staging, restoration limits, and schedule. Harrowgate reviews quantities and interfaces instead of pricing conduit length without the supporting civil work.

Our Work

See real projects across Toronto & Ontario

Commercial and heavy-civil construction, self-performed for developers, contractors, property managers, and municipalities.

View Our Projects

Get a quote for electrical duct bank and underground conduit

Send drawings, a site plan, or a description of the scope. Harrowgate Group is licensed, insured, and WSIB certified.

(416) 629-0721

Licensed, Insured & WSIB Certified · Self-performed and documented on every job

Send your project details

Tell us what you need and we’ll get you a quote. Licensed, insured & WSIB certified · Free, no-obligation quote & on-site assessment.

Free, no-obligation quote & on-site assessment · licensed, insured & WSIB certified.

or
Call (416) 629-0721

Companies We've Worked With

Trusted by Leading Organizations

Harrowgate Group delivers commercial and heavy-civil construction for developers, contractors, institutions, municipalities, and property groups across Ontario.

Popeyes logo Popeyes
Tim Hortons logo Tim Hortons
Subway logo Subway
University of Toronto logo University of Toronto
Madison Group logo Madison Group
RioCan logo RioCan
Women's College Hospital logo Women's College Hospital
Starbucks logo Starbucks
Mazda logo Mazda
TD Bank logo TD Bank
City of Toronto logo City of Toronto
Popeyes logo Popeyes
Tim Hortons logo Tim Hortons
Subway logo Subway
University of Toronto logo University of Toronto
Madison Group logo Madison Group
RioCan logo RioCan
Women's College Hospital logo Women's College Hospital
Starbucks logo Starbucks
Mazda logo Mazda
TD Bank logo TD Bank
City of Toronto logo City of Toronto
Call