Quote-Ready Now Self-Performed Licensed & Insured
Commercial & Heavy-Civil Construction

Shoring and Underpinning

Engineered excavation support and staged foundation transfer, self-performed and managed beside structures, roads, and utilities across the GTA and Ontario. Harrowgate Group self-performs the work to your engineered drawings, load, and finish, and completes it on site across the GTA and Ontario.

Get a Quote

Tell us what you need and we’ll get you a quote. Licensed, insured & WSIB certified · Free, no-obligation quote & on-site assessment.

Free, no-obligation quote & on-site assessment · licensed, insured & WSIB certified.

or
Call (416) 629-0721

Get a Quote

Licensed, insured & WSIB certified · Free, no-obligation quote & on-site assessment.

Free, no-obligation quote & on-site assessment · licensed, insured & WSIB certified.

or
Call (416) 629-0721
Licensed, Insured & WSIB Certified · 20 Years in Business
Licensed, Insured & WSIB-Registered Completed to code & Ontario requirements Built to drawings, self-performed & completed Shipped across Canada & North America
Why Harrowgate Group

Shoring and Underpinning, done right

Built to spec

Built to your engineered drawings, survey, and the real site conditions, not a standard package forced to fit.

Made to last

Heavy-duty steel and finishes chosen for the load, traffic, and environment on site.

Quote-ready

Send specs, drawings, or photos and get a free, no-obligation site visit and estimate with no guesswork.

Code-conscious

Installation and site work completed in accordance with Ontario requirements.

Our Process

Our Process

Shoring supports excavation walls, while underpinning transfers an existing structure's load to deeper or improved support when nearby excavation or changed loading threatens the original foundation. Harrowgate self-performs and manages soldier piles, lagging, walers, bracing, tiebacks where approved, shotcrete or concrete elements, staged pits, load transfer, excavation, and backfill across the GTA and Ontario.

  1. 01 Send your inquiry, drawings, photos, or a description of what you need.
  2. 02 We come measure and assess the site (or work from your specs and drawings).
  3. 03 We build your shoring and underpinning to the engineered drawings on site, finished for the conditions.
  4. 04 We return to deliver and install it, set, levelled, and done right on site.
Shoring and Underpinning being built and completed on site by Harrowgate Group
Completed Shoring and Underpinning installation by Harrowgate Group
Finished On Site

Delivered, installed, and built to last

Self-performed on site to the engineered drawings, coordinated with concrete, servicing, and the surrounding work, then a clean, documented finish.

  • Coordinated with the surrounding build
  • Durable finishes for real-world wear
  • Quote-ready support from spec to delivery
FAQ

Shoring and Underpinning FAQ

When is engineered shoring required in Ontario?

Shoring is required when an excavation cannot meet a regulatory exception through depth, stable rock, no-entry conditions, or compliant slopes. An engineered system is mandatory for trenches over 6 metres deep or 3.6 metres wide and is often necessary sooner beside buildings, roads, utilities, groundwater, or property lines. The site-specific design governs.

What is the difference between shoring and underpinning?

Shoring restrains soil and supports an excavation face. Underpinning strengthens or deepens support beneath an existing foundation and transfers its load in stages. A project may need both: shoring to control the cut and underpinning where the adjacent footing lies within the excavation influence zone or cannot tolerate predicted movement.

How are adjacent buildings monitored during excavation?

The engineer's plan can use survey points, crack gauges, inclinometers, vibration monitors, or piezometers at defined locations and frequencies. Baseline readings are taken before work. Harrowgate protects instruments, reviews results against alert and action thresholds, and follows the specified response, which may include stopping excavation, adding support, or revising sequencing.

Can tiebacks extend beneath neighbouring property?

Only when the design is approved and the required legal rights, agreements, and permits are in place. Without those rights, the engineer may select internal bracing, rakers, secant or tangent piles, or another system that remains within the project limits. Harrowgate confirms anchor geometry and property constraints before drilling equipment mobilizes.

How is an underpinning pin loaded against the old footing?

After the new pin reaches the required strength, the specified transfer zone is completed using dry-pack, non-shrink material, jacking, or another engineered method. Bearing faces must be sound and fully filled. Harrowgate follows the numbered sequence and does not open the neighbouring pin until inspection and load-transfer prerequisites are satisfied.

What causes movement behind a shoring wall?

Movement can result from wall deflection, ground loss through lagging, delayed braces, anchor creep, dewatering settlement, weak toe support, surcharge, or excavation below the designed stage. Harrowgate limits open lifts, closes gaps promptly, controls water with filtration, installs support on sequence, and uses monitoring feedback before authorizing the next cut.

What documents are needed for shoring pricing?

Provide the sealed support design and sequence, geotechnical and groundwater reports, utility survey, property and easement information, adjacent-foundation details, pre-condition and monitoring requirements, excavation and permanent-work sequence, access constraints, spoil route, anchor permissions, load testing, permit conditions, and removal or abandonment details for temporary components.

Our Work

See real projects across Toronto & Ontario

Commercial and heavy-civil construction, self-performed for developers, contractors, property managers, and municipalities.

View Our Projects

Get a quote for shoring and underpinning

Send drawings, a site plan, or a description of the scope. Harrowgate Group is licensed, insured, and WSIB certified.

(416) 629-0721

Licensed, Insured & WSIB Certified · Self-performed and documented on every job

Send your project details

Tell us what you need and we’ll get you a quote. Licensed, insured & WSIB certified · Free, no-obligation quote & on-site assessment.

Free, no-obligation quote & on-site assessment · licensed, insured & WSIB certified.

or
Call (416) 629-0721

Companies We've Worked With

Trusted by Leading Organizations

Harrowgate Group delivers commercial and heavy-civil construction for developers, contractors, institutions, municipalities, and property groups across Ontario.

Popeyes logo Popeyes
Tim Hortons logo Tim Hortons
Subway logo Subway
University of Toronto logo University of Toronto
Madison Group logo Madison Group
RioCan logo RioCan
Women's College Hospital logo Women's College Hospital
Starbucks logo Starbucks
Mazda logo Mazda
TD Bank logo TD Bank
City of Toronto logo City of Toronto
Popeyes logo Popeyes
Tim Hortons logo Tim Hortons
Subway logo Subway
University of Toronto logo University of Toronto
Madison Group logo Madison Group
RioCan logo RioCan
Women's College Hospital logo Women's College Hospital
Starbucks logo Starbucks
Mazda logo Mazda
TD Bank logo TD Bank
City of Toronto logo City of Toronto
Call