For most cutting and coring in Ontario, ground penetrating radar (GPR) is the right first scan. It works from one side of the slab, needs no exclusion zone and maps rebar, post-tension tendons and conduit with depth. Concrete X-ray is the backup when GPR cannot tell you what an object is.
By Harrowgate Group
Last updated: October 24, 2026
The choice matters because a core bit or saw blade that hits a post-tension tendon, a live conduit or a major bar can injure a worker and damage the structure. Scanning is the step that turns “we think the slab is clear” into a marked, documented layout. Our GPR concrete scanning crews scan before most openings we cut, and the method we choose depends on the slab, the access and what the scan has to prove.
Which method should you use first?
Use GPR first on almost every slab, wall and deck. Add X-ray only when GPR leaves a real question open, such as a dense reinforcing mat, an unidentified target or a high-consequence opening in a post-tensioned slab.
| Question | GPR | Concrete X-ray |
|---|---|---|
| Access needed | One side of the concrete | Both sides of the concrete |
| What it gives you | Position and depth of targets | A picture of what the object is |
| Depth information | Yes, once calibrated | Little or none |
| Crew and controls | One operator, little effect on other trades | Qualified crew, restricted zone during exposure |
| Regulation | Standard site safety | Ontario Regulation 861 applies |
| Main weakness | Needs interpretation; blocked by dense metal and moisture | Slow, needs two-sided access, no depth |
How does GPR work on a concrete slab?
GPR sends short radar pulses into the concrete and records the reflections. Metal reflects strongly, so rebar and tendons show as bright arcs, and the time of each reflection gives depth once the operator has calibrated the speed of the signal in that slab.
As a manufacturer of GPR equipment explains in Screening Eagle’s guide to what GPR can reveal, the dielectric constant of concrete varies with mix and water content, so depth readings need calibration for each mix. The operator marks the results directly on the surface, usually as a grid, so the cutting crew sees them with their own eyes.
What can GPR miss or get wrong?
GPR can be blind below dense steel, in wet or very fresh concrete and in steel fibre concrete. Plastic conduit can also be hard to see because it is electrically similar to concrete.
- Metal shielding. Metal reflects nearly all of the radar energy, so nothing below it can be seen. A tight top mat can hide a second layer or a tendon underneath.
- Moisture. Water absorbs and scatters the signal, which blurs the image and reduces depth. Fresh concrete should not be scanned until it has cured and dried.
- Steel fibres. Fibres in the mix block the waves, so there may be almost no usable depth.
- Plastic conduit. PVC and similar conduit sits close to concrete in electrical properties, so it can be faint or missed.
- Interpretation. GPR shows that something is there. The operator decides whether it is a bar, a tendon or a conduit from its depth, spacing and pattern.
That last point is where experience matters. A scan is only as good as the person reading it, which is why we ask scanning crews to mark and name each target, not just draw lines.
When is concrete X-ray still the better call?
X-ray earns its place when you need to know what an object is, not just where it is. It images through the concrete to show a bar, a bundle or a tendon directly, so it can settle an ambiguous GPR reading.
Typical cases are a congested slab where GPR cannot see past the top mat, a post-tensioned slab where one wrong cut is a serious problem, or a large opening where the owner or engineer wants a second method on record. X-ray gives little depth information, so it is normally paired with GPR for depth rather than used alone.
What does X-ray add in practical and regulatory terms?
X-ray needs access to both faces of the concrete, a controlled area while it runs and a qualified crew. That can shut down work nearby and push a schedule.
In Ontario, Regulation 861 (X-Ray Safety) under the Occupational Health and Safety Act applies to workplaces where an X-ray source is present or used. It requires the employer to be registered with a Director before using an X-ray source at a workplace, to designate a competent person to direct the safe use of the source, to supply personal dosimeters to X-ray workers and to control access with barriers and warning signs where portable equipment is used and the exposure may exceed the stated limit. GPR carries none of these requirements, which is a large part of why it is the default.
Are there other methods besides GPR and X-ray?
Yes, and they are often used alongside GPR. Electromagnetic cover meters and rebar locators are useful for quick, shallow checks of bar position. Structural drawings, as-built records and a visual review of the slab edge and soffit all feed into the plan. None of these replaces a scan before an opening is cut.
Whatever the method, scanning does not replace the engineer. Cutting through a beam, a column or a post-tensioned slab needs engineering review and often a shoring or sequencing plan. Our concrete cutting and coring work is planned around that review, and selective demolition projects add it to the demolition sequence. If your opening is part of a larger demolition scope, our guide to what a commercial demolition permit requires in Ontario covers the approvals around it. If a scan shows reinforcing that has to be cut or relocated, see our rebar supply and installation work and our structural concrete work for what follows.
A practical checklist before scanning
Have these ready before the crew arrives, and the scan will be faster and more useful.
- Marked openings. Locations and sizes of each core or cut, drawn or painted on the surface.
- Drawings. Structural and architectural drawings, and any as-built or previous scan records.
- Slab type. Whether the slab is conventionally reinforced, post-tensioned, a topping over precast or a metal deck.
- Access. Both-side access if X-ray may be needed, plus power, lifts and hoisting.
- Surface condition. A reasonably clean, dry, flat surface. Remove coverings, equipment and debris from the scan area.
- Other trades. Notice to neighbouring trades and tenants, especially if X-ray is in play.
- What lies below. What sits under the slab, such as occupied space, mechanical rooms or electrical rooms, so the crew can protect people and equipment.
- Who signs off. The engineer or consultant who will review the results before cutting begins.
What should the scan deliverable include?
Ask for marks on the concrete and a written record: the location of each core or cut, the targets found, their depth and your next step if the scan raised a flag. If an opening conflicts with a tendon or a major bar, the answer is usually to shift the opening, change its size or involve the engineer, not to cut and hope.
Choosing and sequencing the work
On most jobs the sequence is simple: review the drawings, scan with GPR, mark the slab, have the engineer confirm any openings that touch reinforcing, then cut or core. If something is unclear after the GPR scan, add a second method before the blade goes in. It is faster to resolve on the surface than to repair the damage later.
To plan scanning with your cutting or coring scope, start with our GPR concrete scanning page and tell us what you are opening and why.
Frequently asked questions
Can GPR find post-tension cables before I core a slab?
Yes, GPR images metal in a slab, including post-tension tendons, and the operator reads their spacing and depth to tell them from ordinary rebar. If the pattern is unclear, the slab is congested or the drawings disagree with the scan, the usual next step is a second method or a different core location.
Does concrete X-ray give me the depth of the rebar?
Not reliably. An X-ray image shows what an object is, but it gives little or no depth information, so depth is usually taken from a GPR scan or from the structural drawings. That is why the two methods are often used together.
Is X-ray scanning of concrete regulated in Ontario?
Yes. Ontario Regulation 861 under the Occupational Health and Safety Act covers X-ray sources at workplaces, including employer registration, a designated competent person, dosimetry for X-ray workers and controlled access during exposure. GPR does not emit ionizing radiation and is not covered by that regulation.
How soon after a pour can new concrete be scanned with GPR?
Fresh concrete holds a lot of free water, and water absorbs radar energy and blurs the image. Manufacturers advise against scanning fresh concrete, so wait until it has cured and dried enough for the signal to travel. Your scanning contractor can advise on timing for your mix and slab.
Do I still need drawings if the slab has been scanned?
Yes. A scan shows what is in the concrete where it was scanned, and drawings show intent, load paths and what the engineer expects to find. Giving the scanning crew both the drawings and the proposed opening sizes lets them flag any mismatch before a blade or bit touches the slab.
Get a quote for your project
Tell us about the site, the scope, and your timeline. We review it and reply with the next step.