Concrete Slab Thickness, Joints and Reinforcing Guide Inputs: use: Driveway, passenger vehicles; slab: 6.0 m by 4.0 m; subgrade: firm Result: - Use: Driveway, passenger vehicles - Minimum thickness: 100 mm (4 in) - Subbase: Crushed stone or gravel, minimum 100 mm (4 in) compacted, compacted to 95% density - Surface slope: Minimum 1/4 in per foot (about 2%) for drainage - Control joint spacing: 2.4 to 3.0 m (8 to 10 ft) - Control joint depth: At least 25 mm (one quarter of the thickness) - Panel shape: As square as possible, length no more than 1.5 times width (up to 4.5 m by 3.0 m) - Joint grid for this slab: 2 by 2 panels (1 joint across, 1 joint along) - Concrete volume: 2.40 m³ (3.14 yd³) before waste - Reinforcing: No fixed band: see the note below Reinforcing: - When a slab is jointed into short panels, distributed steel is not necessary (ACI 330R-08, quoted in the ASCC and NRMCA FAQ). - Welded wire mesh adds no structural capacity. Its job is to keep cracks tight, and it only works if it is placed in the right position. - Dowels are not needed for most parking lot conditions, and in pavements of 7 in (about 175 mm) or less they can be impractical (ACI 330R-08). - Rebar, fibre or mesh in a slab is a specification decision for the engineer or the owner. The sources read give no thickness or bar size for it. Joints: - Isolation joints (compressible filler, full slab depth) go where the slab meets walls, foundations, steps and other fixed objects. - Joint spacing here is 24 to 30 times the thickness (2 to 2.5 times the thickness in inches, in feet), capped at 4.5 m (15 ft). Note: Concrete within the public right-of-way, including a driveway apron, may be subject to municipal requirements. Check the thickness with your municipality before construction. Limits: Guidance only, not a slab design. Loads, soil, frost, drainage, concrete mix and the municipal or project specification decide the final thickness and reinforcing, and an engineer designs parking lots, truck pads and anything carrying heavy equipment. Source: Illinois Ready Mixed Concrete Association, Concrete Guide for Residential Exterior Flatwork (thickness, subbase, drainage, joints); American Society of Concrete Contractors and NRMCA, FAQ About Concrete Parking Lot Design and Construction Specifications, 2018, quoting ACI 330R-08 (reinforcing, dowels, subbase, maximum joint spacing). Tool: https://harrowgategroup.com/concrete-slab-thickness-and-reinforcing-guide/ Free quote: https://harrowgategroup.com/concrete-slab-thickness-and-reinforcing-guide/#audience-quote